beautypg.com

Festo Кабели и принадлежности User Manual

Page 386

background image

8. Diagnosis and error treatment

8−30

Festo P.BE−SPC200−EN en 0901d

Fault class 8:

NC Editor, Upload/download or operation execution fault

Fault
stage

Fault
message

Operating status / fault explanation

Eliminating faults

D

nnn01x08
ppp01x08

Syntax fault or non−permitted program
number entered

·

Correct entry

ppp02x08

When using the control panel:
Ĉ Non−permitted program number selected,

program cannot be created as it already
exists or program cannot be opened as it
does not exist.

Ĉ No free memory space

When using WinPISA:
Ĉ Program could not be loaded When the

fault is deleted, the memory of the SPC200
will be re−assigned.

·

Correct entry

If the maximum number of NC
records is not yet reached:

·

Carry out program modificaĆ
tion with WinPISA; if necessĆ
ary the memory will be
re−assigned.

·

Load the program again
when the memory has been
re−assigned.

nnn03x08

Non−permitted record number

·

Correct entry

ppp04x08 No free memory space for new program

·

Delete unnecessary
programs and NC records

ppp05x08

Test sum fault

·

Servicing required

00006x08
to
0000Ax08

Fault in Upload/Download with WinPISA

·

Check connecting cable and
diagnostic module; if necessĆ
ary set lower baud rate

0000Bx08 Enable signal missing

·

Apply a 1−signal at the
ENABLE input

0000Cx08

System has stopped, there is a 0−signal at
the STOP input

·

Apply a 1−signal at the STOP
input

0000Dx08 Starting program does not exist

·

Correct the number of the
starting program

0000Ex08

Command not permitted in this operating
mode

·

Do not use this command in
the current operating mode
or modify the operating mode

zzz = Additional information
yy = Fault number
x

= Axis identifier (0 = fault is not axis−related)

ppp = Program number
nnn = NC record number of the accessing NC command