Dismantling and repairs

Dismantling:

Please note
The actuators may perform sudden unexpected movements.

S Make sure that both linear module and clamping unit are exhausted.

If required:

S

Use the opportunity to have your HMP−...−KP overhauled by the Festo repair
service.

In all other aspects, the clamping unit does not require any maintenance.

8

Eliminating faults

Fault

Possible cause

Remedy

Guide tube moves
although clamping

Mass too large

Reduce the mass

although clamping
unit is not pressurized

Dirt on the clamping rod

Clean the clamping rod if it is
dirty

Incorrect actuation

Check the pneumatic circuit
diagram

Clamping unit defective

Return the HMP−...−KP to
Festo

Guide tube clamped
although clamping
unit is pressurized

Insufficient pressure on the
clamping unit

Pressurize the clamping unit
with the same pressure as the
linear module (at least 4 bar).

Piston rod strikes end
position unbraked
when clamping unit is
pressurized

Linear module is not
pressurized / incorrectly
pressurized

Commissioning as per
Commissioning"

Fig. 22