7 dismantling and repairs, 8 eliminating faults, 7dismantling and repairs – Festo Линейные модули HMP User Manual
Page 24: 8eliminating faults
HMP−...−KP−...
Festo HMP−...−KP−... 0408b English
24
7
Dismantling and repairs
Dismantling:
Please note
The actuators may perform sudden unexpected movements.
S Make sure that both linear module and clamping unit are exhausted.
If required:
S
Use the opportunity to have your HMP−...−KP overhauled by the Festo repair
service.
In all other aspects, the clamping unit does not require any maintenance.
8
Eliminating faults
Fault
Possible cause
Remedy
Guide tube moves
although clamping
Mass too large
Reduce the mass
although clamping
unit is not pressurized
Dirt on the clamping rod
Clean the clamping rod if it is
dirty
Incorrect actuation
Check the pneumatic circuit
diagram
Clamping unit defective
Return the HMP−...−KP to
Festo
Guide tube clamped
although clamping
unit is pressurized
Insufficient pressure on the
clamping unit
Pressurize the clamping unit
with the same pressure as the
linear module (at least 4 bar).
Piston rod strikes end
position unbraked
when clamping unit is
pressurized
Linear module is not
pressurized / incorrectly
pressurized
Commissioning as per
Commissioning"
Fig. 22