3
Conditions of use
Please note
If the speed is
braked, the HMP−...−KP
could be damaged.
S With normal regular clamping ensure
that:
ć the clamp is only released in the
pressurized end position of the
linear module.
ć the clamping unit is only pressurized
and exhausted when the piston rod
is standing completely still.
ć there are no dynamic forces.
Please note
S These general conditions for the correct and safe use of the Linear module
HMP−..." must be observed at all times.
The technical specifications of the clamping unit type HMP−...−KP may limit
the specifications for linear module type HMP−... in the operating instrucĆ
tions.
4
Fitting
Fitting mechanical components
Please note
Deformed components may cause a functional failure.
S Make sure that no transverse forces are applied on housing 2, or on the
clamping rod of the HMP−...−KP.
Fig. 4