beautypg.com

Service procedures – Panasonic 36PSU1U6 User Manual

Page 170

background image

4-6

4. Service procedures

Judgment condition

Clear condition

P29

F04

F06

Alarm

contents

Judgment and correction

Recovery at restart

Recovery at restart

Recovery at restart

Recovery at restart

Recovery at restart

Current detection
circuit trouble
• AC current value is

high even when
compressor is
stopped.

Inverter stops after alarm is
detected. Alarm is output
when inverter stops (pre-trip)
consecutively 4 times.

1. Stops immediately when

restarted.

• Layer short in the

compressor

2. Check inverter control PCB.

• Wiring trouble

Compressor motor
output trouble,
Inverter compressor
trouble,
MDC trouble

Inverter stops after alarm is
detected.

1. Refrigerant cycle trouble,

overload operation

2. Loose screws and contact

failure between HIC control
PCB and radiating plate

3. Cooling failure of radiating

plate

4. Check outdoor unit PCB

wiring.

Compressor does not
run. (Overcurrent
protection circuit
activates after a certain
period of time following
compressor start.)

Inverter stops after alarm is
detected.

1. Compressor trouble (locked,

etc.)

• Replace the compressor.

2. Compressor wiring trouble

(missing phase)

Compressor
breakdown
• Starts to operate but

operating frequency
drops and
compressor stops.

Inverter stops after alarm is
detected.

1. Check power voltage: AC

2. Refrigerant cycle overload

operation

3. Check AC current detection

circuit.

Inverter control PCB
position detection
circuit trouble

Inverter stops after alarm is
detected.

Position detection circuit is
activated even when the
compressor 3P connector is
disconnected and the
compressor operated.
• Replace the inverter control

PCB.

Disconnection, open
circuit, or short circuit
in discharge temp.
sensor (TD)

Sensor detection trouble

minutes have elapsed after
compressor stopped).
(Open circuit)

Automatic recovery

Automatic recovery

1. Check discharge temp.

sensor (TD).

2. Check outdoor unit control

PCB.

Open circuit or short circuit

Disconnection, open
circuit, or short circuit
in outdoor heat
exchanger temp.
sensor (C1)

1. Check outdoor heat

exchanger temp. sensor (C1).

2. Check outdoor unit control

PCB.

Remote

controller

alarm display

Open circuit or short circuit

Automatic recovery

2. Check outdoor unit control

PCB.

y

r

e

v

o

c

e

r

c

i

t

a

m

o

t

u

A

t

i

u

c

r

i

c

t

r

o

h

s

r

o

t

i

u

c

r

i

c

n

e

p

O

2

1

F

Disconnection, open
circuit, or short circuit
in intake temp. sensor
(TS)

1. Check intake temp. sensor

(TS).

2. Check outdoor unit control

PCB.

203 V

± 20 V or 230 V ± 23 V.

26, 36 MODEL:

42 MODEL:
Sensor defection trouble
(194

°F or higher when 60

minutes have elapsed after
compressor stopped).
(Open circuit)

F07

Disconnection, open
circuit, or short circuit
in outdoor heat
exchanger temp.
sensor (C2)

1. Check outdoor heat

exchanger temp. sensor (C2).

Open circuit or short circuit

Automatic recovery

2. Check outdoor unit control

PCB.

F08

Disconnection, open
circuit, or short circuit
in outdoor air temp.
sensor (TO)

1. Check outdoor air temp.

sensor (TO).

(194

°F or higher when 15

4

SM830203-01_PAC-i_US-letter.indb6 6

SM830203-01_PAC-i_US-letter.indb6 6

2012/01/26 10:32:03

2012/01/26 10:32:03