Page 62
Step 1:
Secure the rack mounting bracket to two sides of the monitor using the supplied
retention screws (Figure 3-17). Each bracket requires four screws.
Step 2:
Secure the rack mounting bracket to the rack by inserting and tightening the
supplied mounting nuts and bolts (Figure 3-17). Each bracket requires three
nuts and bolts for installation.
Step 0:
4.7.4 Arm Mounting
The PPC-5xxx-9455 is VESA (Video Electronics Standards Association) compliant and
can be mounted on an arm with a 100 mm interface pad. To mount the PPC-5xxx-9455 on
an arm, please follow the steps below.
Step 1:
The arm is a separately purchased item. Please correctly mount the arm onto
the surface it uses as a base. To do this, refer to the installation documentation
that came with the mounting arm.
NOTE:
When purchasing the arm please ensure that it is VESA compliant and
that the arm has a 100 mm interface pad. If the mounting arm is not
VESA compliant, it cannot be used to support the PPC-5xxx-9455 flat
panel PC.
Step 2:
Once the mounting arm has been firmly attached to its surface, lift the
PPC-5xxx-9455 flat panel PC onto the interface pad of the mounting arm.
Step 3:
Align the retention screw holes on the mounting arm interface with those in the
PPC-5xxx-9455 flat panel PC. The PPC-5xxx-9455 flat panel PC arm mount
retention screw holes are shown in Figure 3-18.