Table 33. Jack Detection Registers

Battery Measurement

The IC measures the voltage applied to SPKLVDD (typically the battery voltage) and reports the value in register 0x03.
This value is also used by the speaker limiter circuitry to set accurate thresholds. When the battery measurement func-
tion is disabled, the battery voltage is user programmable.

Table 34. Battery Measurement Registers

REGISTER

BIT

NAME

DESCRIPTION

0x02

(Read Only)

6

JKSNS

JACKSNS State
Reports the status of JACKSNS when JDETEN = 1, MBEN = 1, BIASEN = 1, and
VCMEN = 1.
0 = JACKSNS low
1 = JACKSNS high

0x4B

7

JDETEN

Jack Detection Enable
0 = Disabled
1 = Enabled

1

JDEB

Jack Detection Debounce
Configures the debounce time for setting JDET.
00 = 25ms
01 = 50ms
10 = 100ms
11 = 200ms

0

REGISTER

BIT

NAME

DESCRIPTION

0x03

4

VBAT

Battery Voltage
Read VBAT when V

BATEN

= 1 to determine V

SPKLVDD

. Program VBAT when V

BATEN

= 0 to allow proper speaker amplifier signal processing. Calculate the battery voltage
using the following formula:
V

BATTERY

= 2.55V + [VBAT/10]

3
2
1
0

0x51

7

SHDN

See Power Management

6

VBATEN

Battery Measurement Enable. Enables an internal ADC to measure V

SPKLVDD

.

0 = Disabled (register 0x03 readable and writeable)
1 = Enabled (register 0x03 read only)

3

PERFMODE

See the Power Management section.

2

HPPLYBCK

See the Power Management section.

1

PWRSV8K

See the Power Management section.

0

PWRSV

See the Power Management section.