Kohler custom Bodyspa 116347-2 User Manual
Page 9
116347Ć2Ć
AA
(A)
10
Kohler Co., Kohler, WI
CUSTOM BODYSPA INSTALLATION INSTRUCTIONS
All information in this manual is based upon the latest product information available at the time of publication.
At Kohler, we constantly strive to improve the quality of our products; we therefore reserve the right to make
changes in product characteristics, packaging, or availability at any time without notice.
THE CUSTOM BODYSPA IS INTENDED FOR INDOOR USE ONLY.
IMPORTANT! READ THIS BEFORE YOU
BEGIN.
This Custom BodySpa operates at flow rates up to
80 gallons per minute. To achieve a watertight
installation, it is critical that you follow all the
design and installation instructions carefully. Pay
particular attention to leveling and sealing details
to obtain a satisfactory installation. A
WATERPROOFING MEMBRANE OR
APPLIED COMPOUND MUST BE
INSTALLED TO THE ENTIRE FLOOR AND
WALL SURFACES WITHIN THE CUSTOM
BODYSPA ROOM.
SERIAL NUMBERS
Model No. (SKU)
KĆ1000 Tower
Serial No.
Model No. (SKU)
KĆ1001 Pump Kit
Serial No.
HOW TO USE THESE INSTRUCTIONS
IMPORTANT! It is critical that you follow the
installation sequence and details in the steps that follow
to successfully install and operate your Custom
BodySpa. A series of colorĆcoded Check Point boxes
are included to assist you. You need to complete the
steps and requirements listed at each Check
Point before you proceed to the next series of
installation steps. This will prevent costly repairs and
rework due to unfamiliarity with custom bath and
shower installations. If necessary, consult with a proven
expert in custom installations before attempting this
installation.
Kohler Co. shall not be responsible for leakage that
occurs as a result of inadequate or poor assembly or
installation techniques.
TABLE OF CONTENTS
FOR YOUR
INSTALLATION INSTRUCTIONS
HOW TO USE THESE INSTRUCTIONS
10
. . . . . .
SERIAL NUMBERS
10
. . . . . . . . . . . . . . . . . . . . . . . . .
IMPORTANT SAFETY INSTRUCTIONS
11
. . . . . .
INSTALLER HAZARD NOTIFICATION
11
. . . . . . .
FACTORYĆASSEMBLED FEATURES
11
. . . . . . . . .
PRODUCT MODIFICATIONS
11
. . . . . . . . . . . . . . . .
CONNECTIONS AND SERVICE ACCESS
11
. . . . .
PRODUCT INSPECTION
11
. . . . . . . . . . . . . . . . . . . .
ELECTRICAL REQUIREMENTS
11
. . . . . . . . . . . . .
STUD POCKET PREPARATION
12
. . . . . . . . . . . . .
PLUMBING PREPARATION
13
. . . . . . . . . . . . . . . . .
INSTALL THE TOWER MOUNTING FRAME 13
.
INSTALL THE PUMP BOX
13
. . . . . . . . . . . . . . . . . .
INSTALL VARIABLE FLOW VALVE
14
. . . . . . . . . .
INSTALL THE SUCTION BRACKET
15
. . . . . . . . .
SOLVENT WELD TUBING
16
. . . . . . . . . . . . . . . . . .
ELECTRICAL CONNECTIONS
16
. . . . . . . . . . . . . .
INSTALL CABLE (OUTLET BOX)
17
. . . . . . . . . . . . .
INSTALL CABLE
17
. . . . . . . . . . . . . . . . . . . . . . . . . . . .
INSTALL WATERPROOFING MEMBRANE
18
. . . .
INSTALL SUCTION BUSHING
18
. . . . . . . . . . . . . . .
INSTALL CEMENT BOARD
19
. . . . . . . . . . . . . . . . . .
CONSTRUCT FOOTBATH BASIN
19
. . . . . . . . . . . . .
INSTALL WALL MATERIAL
19
. . . . . . . . . . . . . . . . . .
INSTALL FINISHED MATERIAL
20
. . . . . . . . . . . . .
INSTALL SUCTION ASSEMBLY
20
. . . . . . . . . . . . . .
INSTALL FAUCET TRIM, SPOUT, DRAIN
21
. . . . .
INSTALL DOOR ENCLOSURE
21
. . . . . . . . . . . . . . . .
INSTALL THE TOWER
22
. . . . . . . . . . . . . . . . . . . . . .
INSTALL THE KEYPAD
23
. . . . . . . . . . . . . . . . . . . . . .
WATER TEST THE SYSTEM
24
. . . . . . . . . . . . . . . . .
CLEANĆUP AFTER INSTALLATION
24
. . . . . . . . . .
TROUBLESHOOTING
25
. . . . . . . . . . . . . . . . . . . . . . .
INST
ALLA
TION