beautypg.com

Inst alla tion – Kohler custom Bodyspa 116347-2 User Manual

Page 22

background image

116347Ć2Ć

AA

(A)

Kohler Co., Kohler, WI

23

INSTALL THE KEYPAD

CAUTION: Risk of personal injury or

product damage. The metal plate must be

installed flush with the finished wall or

slightly recessed (maximum 1/4Ćinch).

Feed the cable through the hole in the metal plate.

Use two flathead screws to attach the metal plate

to the outlet box or finished wall material so the

metal plate is flush with the finished wall or

slightly recessed (maximum 1/4Ćinch).
Snap the keypad modular plug into the keypad

cable jack.
Apply silicone sealant to each of the keypad screw

holes and around the keypad edges, and secure the

keypad to the metal plate with four panhead

screws.

CAUTION: Risk of personal injury or

product damage. Prevent water damage to

the keypad by applying silicone sealant as

instructed.

IMPORTANT! Apply a continuous bead of clear

silicone sealant to the cover plate sealant

grooves, as shown.
Slip the center pin at the top of the cover plate up

through the hole in the keypad. Secure the cover

plate to the keypad with a panhead screw.
Select the bottom cap - it contains a small pinhole,

and has a small notched area along the contact

surface edge.
IMPORTANT! Apply clear silicone sealant to

the back surface of the bottom cap, and also to

the edge that contacts the cover plate. Align

the bottom cap holes with the cover plate pins,

and push the cap into place. Repeat for the top

cap.
Remove any excess sealant.

Check Point #9

-

Faucet trim and spout installed.

-

Drain assembly installed.

-

Footbath basin filled with water and checked for leakage.

-

Door enclosure installed.

-

Tower installed.

-

Keypad installed and sealed with silicone sealant.

-

Keypad wiring connections made.

INST

ALLA

TION