Inst alla tion inst alla tion – Kohler custom Bodyspa 116347-2 User Manual
Page 21
116347Ć2Ć
AA
(A)
22
Kohler Co., Kohler, WI
INSTALL THE TOWER
Locate the pin at the bottom left corner of the tower.
Insert this pin into the bottom left corner hole in the
mounting frame bracket. Now line up the hole at the
top left corner of the tower with the slotted hole in
the mounting frame, and thread a 3/8Ćinch bolt
through the mounting frame and into the tower.
Securely wrench tighten the bolt.
Route the tower cable through the large hole in the
mounting frame. Snap the tower cable modular plug
into the corresponding jack of the control box. Install
the large strain relief bushing over the tower cable,
and insert it into the large mounting frame hole.
NOTE: National Electrical Code requires that you
permanently separate the highĆ and lowĆvoltage
cables.
Route the waterfall light wires through the small
hole in the back of the mounting frame. Connect the
waterfall light wire connectors to the transformer
terminals - white to white; black to black. Install the
small strain relief bushing over the waterfall light
wires, and insert it into the small mounting frame
hole.
Securely handtighten the tower union nut to the
mounting frame union. Be sure the union OĆring is
in place.
Carefully pivot the tower closed. Line up the holes at
the top and bottom right corners of the tower with
the slotted holes in the mounting frame. Thread a
3/8Ćinch bolt through the mounting frame and into
the tower at the top and bottom. Tighten the bolts
securely, but do not overtighten.
You will water test and inspect the tower and
mounting frame later, so you may want to only
install and handtighten one of the required bolts at
this time. Both bolts will need to be securely
tightened later.
INST
ALLA
TION
INST
ALLA
TION