4 9406-mma ipl performance measurements (normal), 5 9406-mma ipl performance measurements (abnormal) – Intel AS/400 RISC Server User Manual
Page 275

16.4 9406-MMA IPL Performance Measurements (Normal)
The following tables provide a comparison summary of the measured performance data for a normal and
abnormal IPL. Results provided do not represent any particular customer environment.
Measurement units are in minutes and seconds
34:27
32:03
17:58
9:42
8:47
Total
2:22
2:41
2:12
1:23
:48
OS/400
9:58
10:05
7:53
5:07
4:49
SLIC
22:07
19:17
7:53
3:12
3:10
Hardware
iV6R1
GA3 Firmware
16 Way
9406-MMA
7061
512 GB
1000 DASD
iV5R4M5
GA1 Firmware
16 Way
9406-MMA
7061
512 GB
1000 DASD
iV5R4M5
GA1 Firmware
8 Way
9406-MMA
7056
96 GB
432 DASD
iV6R1
GA3 Firmware
4 Way
9406-MMA
7051
32 GB
30 DASD
iV5R4M5
GA1 Firmware
4 Way
9406-MMA
7051
32 GB
30 DASD
Table 16.4.1 iV5R4M5 Normal IPL - Power-On (Cold Start)
Generally, the hardware phase is composed of C1xx xxxx, C3xx xxxx and C7xx xxxx. SLIC is
composed of C200 xxxx and C600 xxxx. OS/400 is composed of C900 xxxx SRCs to the System i server
console sign-on.
16.5 9406-MMA IPL Performance Measurements (Abnormal)
Measurement units are in minutes and seconds.
42:49
52:00
45:08
20:44
18:44
Total
20:47
29:27
28:06
5:04
4:22
OS/400
3:28
4:02
2:32
1:29
3:09
SLIC
re-ipl
3:04
2:28
3:18
2:24
2:00
Shutdown
re-ipl
10:56
11:35
7:00
10:45
7:23
SLIC MSD
IPL
with Copy
4:34
4:28
4:12
1:02
1:50
Processor
MSD
iV6R1
GA3 Firmware
16 Way
9406-MMA
7061
512 GB
1000 DASD
iV5R4M5
GA1 Firmware
16 Way
9406-MMA
7061
512 GB
1000 DASD
iV5R4M5
GA1 Firmware
8 Way
9406-MMA
7056
96 GB
432 DASD
iV6R1
GA3 Firmware
4 Way
9406-MMA
7051
32 GB
30 DASD
iV5R4M5
GA1 Firmware
4 Way
9406-MMA
7051
32 GB
30 DASD
Table 16.5.1 iV5R4M5 Abnormal IPL (Partition MSD)
IBM i 6.1 Performance Capabilities Reference - January/April/October 2008
©
Copyright IBM Corp. 2008
Chapter 16 IPL Performance
275