Intel AS/400 RISC Server User Manual
Page 200
In comparing Mirroring and RAID one of the concerns is capacity differences and the hardware
needed. We tried to create an environment where the capacity was the same in both
environments. To do this we built the same size database on “15 35GB DASD using RAID5”
and “14 70GB DASD using Mirroring spread across 2 IOAs”. The protection in the Mirrored
environment is better but it also has the cost of an extra IOA in this low number DASD
environment. For the 30 DASD and 60 DASD environments the number of IOAs needed is
equal.
14.1.7.3
14.1.7.4
IBM i 6.1 Performance Capabilities Reference - January/April/October 2008
©
Copyright IBM Corp. 2008
Chapter 14 DASD Performance
200
RAID-5 compared to Mirroring
0
0.05
0.1
0.15
0.2
0.25
0
5000
10000 15000 20000 25000 30000 35000 40000
571E/574F (15 - 35 GB DASD): IOPLess, RAID-5
571E (14 - 70 GB DASD): IOPLess, 7 Mirrored Pairs 2 IOAs
571E (30 DASD): IOPLess, 15 Mirrored Pairs 2 IOAs
571E/574F (30 DASD): IOPLess, RAID-5 2 IOAs
571E (60 DASD): IOPLess, 30 Mirrored Pairs 4 IOAs
571E/574F (60 DASD): IOPLess, RAID-5 4 IOAs
Workload Throughput
S
y
s
te
m
R
e
sp
o
n
se
T
ime
(
s
e
c
)
RAID-5 compared to Mirroring
0
10
20
30
40
0
2000
4000
6000
8000
10000
571E/574F (15 - 35 GB DASD): IOPLess, RAID-5
571E (14 - 70 GB DASD): IOPLess, 7 Mirrored Pairs 2 IOAs
571E (30 DASD): IOPLess, 15 Mirrored Pairs 2 IOAs
571E/574F (30 DASD): IOPLess, RAID-5 2 IOAs
571E (60 DASD): IOPLess, 30 Mirrored Pairs 4 IOAs
571E/574F (60 DASD): IOPLess, RAID-5 4 IOAs
Ops/Sec
D
A
S
D
R
e
s
p
ons
e T
im
e
(
m
s
)