SR2122 / Insight Manager 7 Service Pack 2 Integration

59

iSCSI SR2122 Storage Router: Getting Started Guide

Figure 37: Valid SR2122 Management Port TCP/IP Configuration

Next, Network Management information must be configured:

Figure 38: Network Management Configuration

Of particular note is the READ Community. This allows for the IM 7 data collection to bring
back the MIB II information. It also makes autodiscovery possible, by supplying the SNMP
MIB II SysOID of the device for identification by IM 7.

In order for SNMP traps to be directed to the IM 7 server, a user will have to fill in the First IP
Address and Second IP Address of the SNMP Trap Host sections. These are the SNMP Trap
Destinations.

It should be noted that IM 7 SP2 only supports SNMP V1 traps. This means that the “Version”
should be set to 1.