beautypg.com

Technical specifications, Quickspecs, Hp proliant dl180 g5 technical specifications – HP ProLiant DL180 G User Manual

Page 28

background image

System Unit

Dimensions (H x W x D)
(with bezel)

3.44x 17.64 x 27.50 in (8.75 x 44.80 x 69.88cm)

Weight
(approximate)

Maximum
(all hard drives, power
supplies and processors
installed)

51.5 lb (19.22 kg)

Minimum
(one hard drive, power
supply and processor
installed)

35.0 lb (13.06 kg)

Input
Requirements
(per power supply)

Rated Line Voltage

100 - 240 VAC

Rated Input Current

9.10 A (at 100 VAC),
4.5 A (at 200 VAC)

Rated Input Frequency 50 to 60 Hz

Rated Input Power

910 W (at 100 VAC),
900 W (at 200 VAC)

BTU Rating

Maximum

3107.82 BTU/hr (at 100 VAC),
3073.67 BTU/hr (at 200 VAC)

Power Specifications

To review typical system power ratings use the Power Calculator which
is available via the online tool located at URL:

http://h30099.www3.hp.com/configurator/calc/
Power%20Calculator%20Catalog.xls

Click on the system of interest. Example: DL180 G5
Follow the instructions of the next screens.

Power Supply Output
(per power supply)

Rated Steady-State
Power

750 W (at 100 VAC),
750 W (at 200 VAC)

Maximum Peak Power 750 W (at 100 VAC),

750W (at 200 VAC)

System Inlet
Temperature

Operating

50° to 95°F (10° to 35°C) at sea level with an
altitude derating of 1.8°F per every 1000 ft
(1.0°C per every 305 m) above sea level to a
maximum of 10,000 ft (3050 m), no direct
sustained sunlight. Maximum rate of change
is 18°F/hr (10°C/hr). The upper limit may be
limited by the type and number of options
installed.
System performance may be reduced if
operating with a fan fault or above 86°F
(30°C).

Non-operating

-22° to 140° F (-30° to 60° C). Maximum rate
of change is 36° F/hr (20° C/hr).

Relative Humidity
(non-condensing)

Operating

10 to 90% relative humidity (Rh), 82.4° F (28°
C) maximum wet bulb temperature, non-
condensing.

Non-operating

5 to 95% relative humidity (Rh), 101.7° F
(38.7° C) maximum wet bulb temperature,
non-condensing.

Altitude

Operating

10,000 ft (3050 m). This value may be limited
by the type and number of options installed.
Maximum allowable altitude change rate is
1500 ft/min (457 m/min).

QuickSpecs

HP ProLiant DL180 G5

Technical Specifications

DA - 12903 Worldwide QuickSpecs — Version 8 — 5.16.2008

Page 28