Calibrate the flags – High End Systems SHOWGUN User Manual
Page 63

CHAPTER 5
Maintenance and Troubleshooting
SHOWGUN
®
User Manual
51
Calibrate the flags
6. Power up the fixture. Unlock the Menu system by pressing Menu button for a few seconds
until the display goes to the 2-line format.
7. Use the left and right arrows
to scroll to the Test option. Press Enter to select.
8. Use the up and down
arrows
to scroll to
SETUP
MOTORS
. Press Enter to
select. Use arrows to scroll
to
YES
and press Enter to
select. Flags will energize
against the standoffs.
9. Using a 2 mm hex key,
loosen the set screw at the
base of the flag.
10. Adjust each flag vertically to
the tickmark on the inside
standoff.
11. Remove the service harness and re-attach the connectors to the 2-phase driver board.
12. Reinsert the bulk head and replace the two 4M socket caps.
13. Home the fixture and test flags. Make sure they are not hitting when fully closing from the
console or the menu system.
Tick marks for
vertical flag
adjustment