Includes

Includes

Includes

Includes

Parallel Card, Triple Chassis for three SmartSlots, User Manual, Web/SNMP Management
Card

Spare parts kits

Spare parts kits

Spare parts kits

Spare parts kits

See APC website

http://www.apcc.com

Documentation

Documentation

Documentation

Documentation

User Manual and Installation Guide

Input

Input

Input

Input

Nominal input voltage

115/200 3PH, 120/208 3PH, 127/220 3PH V

Input frequency

50 Hz programmable +/- 0.5, 1, 2, 4, 6, 8%; 60 Hz
programmable +/- 0.5, 1, 2, 4, 6, 8%

Input connection type

Hardwire 5-wire (3PH + N + G)

Input voltage range for main
operations

170-230 (200 V), 177-239 (208 V), 187-242 (220 V) V

Batteries

Batteries

Batteries

Batteries

Typical backup time at half
load

36.7 minutes

Typical backup time at full load 10.7 minutes

Battery type

Maintenance-free sealed Lead-Acid battery with
suspended electrolyte: leak proof

Typical recharge time **

2 hours

Physical

Physical

Physical

Physical

Maximum height dimensions

55.12 in (140.00 cm)

Maximum width dimensions

39.37 in (100.00 cm)

Maximum depth dimensions

31.50 in (80.01 cm)

Net weight

1,290.00 lbs (586.36 kg)

Shipping Weight

1,340.00 lbs (609.09 kg)

Shipping Height

66.93 in (170.00 cm)

Shipping Width

43.31 in (110.00 cm)

Shipping Depth

35.43 in(90.00 cm)

Color

Dark green (NCS 7020 B50G), Light gray (NCS 2703
G84Y)

Units per Pallet

1.0

Communications and

Communications and

Communications and

Communications and
Management

Management

Management

Management

Interface port

DB-25 RS-232, Contact Closure

Smart Slot Interface Quantity

2

Pre-Installed SmartSlot Cards

AP9606

Control panel

Multi-function LCD status and control console

Audible alarm

Beep for each 52 alarm conditions

Emergency Power Off (EPO)

Yes

Optional Management Device See APC website

http://www.apcc.com

Environmental

Environmental

Environmental

Environmental

Operating Environment

68° to 86° F (20° to 30 °C) (recommended is 68° to 77° F
(20° to 25° C))

Operating Relative Humidity

15% to 80% at 86°F (30°C)

Operating Elevation

0 to 10000 ft (0 to 3050 m)

Storage Temperature

-40° to 158° F (-40° to 70° C)

Storage Relative Humidity

0% to 90%

Storage Elevation

0 to 15,000 ft (0 to 4575 m)

Audible noise at 1 meter from
surface of unit

55 dBA

Online thermal dissipation

4,094 BTU/hour

Protection Class

NEMA 1, NEMA 12

Conformance

Conformance

Conformance

Conformance

Approvals

EN 55022 Class A, ISO 9001, ISO 14001, UL 1778, UL
Listed, cUL Listed

Standard warranty

One-year repair or replace, optional on-site warranties
available, optional extended warranties available

Optional New Service

See APC website

http://www.apcc.com

QuickSpecs

HP 9000 Superdome Servers

HP 9000 Superdome Servers

HP 9000 Superdome Servers

HP 9000 Superdome Servers

(PA-8600, PA-8700 and PA-8800)

(PA-8600, PA-8700 and PA-8800)

(PA-8600, PA-8700 and PA-8800)

(PA-8600, PA-8700 and PA-8800)

Technical Specifications

DA - 11721 North America — Version 13 — April 1, 2005

Page 39

This manual is related to the following products: