beautypg.com

Quickspecs, Hp 9000 superdome servers – HP PA 8800 User Manual

Page 20

background image

OpenView Operations Agent

OpenView Operations Agent

OpenView Operations Agent

OpenView Operations Agent-collects and correlates OS and application events (fee-based)
OpenView Performance Agent

OpenView Performance Agent

OpenView Performance Agent

OpenView Performance Agent-determines OS and application performance trends (fee-based)
OpenView GlancePlus

OpenView GlancePlus

OpenView GlancePlus

OpenView GlancePlus-shows real time OS and application availability and performance data to diagnose
problems (fee-based)
OpenView Data Protector (Omniback II)-

OpenView Data Protector (Omniback II)-

OpenView Data Protector (Omniback II)-

OpenView Data Protector (Omniback II)-backs up and recovers data (fee-based)

In addition, the Network Node Manager (NNM) management station automatically discovers, draws (maps), and monitors
networks and the systems connected to them.

All other OpenView management tools, such as OpenView Operations, Service Desk, and Service Reporter, will be able to
collect and process information from the agents running on the server.

General Site Preparation Rules

General Site Preparation Rules

General Site Preparation Rules

General Site Preparation Rules

AC Power Requirements

AC Power Requirements

AC Power Requirements

AC Power Requirements

The modular, N+1 power shelf assembly is called the Front End Power Subsystem (FEPS). The redundancy of the FEPS is
achieved with 6 internal Bulk Power Supplies (BPS), any five of which can support the load and performance requirements.

Input Power Options

Input Power Options

Input Power Options

Input Power Options

PDCA Product

PDCA Product

PDCA Product

PDCA Product
Number

Number

Number

Number

Source Type

Source Type

Source Type

Source Type Source Voltage

Source Voltage

Source Voltage

Source Voltage (nominal)

PDCA

PDCA

PDCA

PDCA
Required

Required

Required

Required

Input Current Per

Input Current Per

Input Current Per

Input Current Per
Phase (200-240

Phase (200-240

Phase (200-240

Phase (200-240
VAC

VAC

VAC

VAC

Power Required

Power Required

Power Required

Power Required

A5800A
Option 006

3-phase

Voltage range 200-240 VAC,
phase-to-phase, 50/60 Hz

4-wire

44 A Maximum per
phase

2.5 meter UL power cord and OL approved
plug provided. The customer must provide the
mating in line connector or purchase quantity
one A6440A opt 401 to receive a mating in
line connector. An electrician must hardwire
the in line connector to
60 A/63 A site power.

a,b,c

A5800A
Option 007

3-phase

Voltage range 200-240 VAC,
phase-to-neutral, 50/60 Hz

5-wire

24 A Maximum per
phase

2.5 meter power cord and VDE
approved plug provided. The customer must
provide the mating in line connector or
purchase quantity 1 A6440A opt 501 to
receive a mating in line connector. An
electrician must hardwire the in line
connector to
30 A/32 A site power.

a,b,d

a. A dedicated branch is required for each PDCA installed.
b. In the U.S.A, site power is 60 Amps; in Europe site power is 63 Amps.
c. Refer to Option 006 and 007 Specifics Table

Option 006 and 007 Specifics Table

Option 006 and 007 Specifics Table

Option 006 and 007 Specifics Table below for detailed specifics related to this option.

d. In the U.S.A. site power is 30 Amps; in Europe site power is 32 Amps.

Console Device

Console Device

Console Device

Console Device

PA-800 Superdome integrates console functionality into the Support Management Station. Note that this SMS/Console is
also used on Integrity Superdome.

QuickSpecs

HP 9000 Superdome Servers

HP 9000 Superdome Servers

HP 9000 Superdome Servers

HP 9000 Superdome Servers

(PA-8600, PA-8700 and PA-8800)

(PA-8600, PA-8700 and PA-8800)

(PA-8600, PA-8700 and PA-8800)

(PA-8600, PA-8700 and PA-8800)

System Management Features

DA - 11721 North America — Version 13 — April 1, 2005

Page 20

This manual is related to the following products: