background image

Power supply diagnostic
LED

Yes

Power Button

Yes, ACPI multi-function

Power LED

Yes, blue (normal), red (fault)

Hard drive activity LED Yes, green

Internal speaker

Yes

System/Emergency ROM
Flash Recovery

Recovers corrupted system BIOS.

OS CD (Restore OS CD)Restores computer to its original factory shipping Operating System - No recovery CDs will ship with

Windows XP, Vista or Linux - an ISO image will be available on an HD partition.

ASF 2.0 support (Alert
Standard Format)

Industry-standard specification for network alerting in operating system-absent environments

Cooling Solutions

Air cooled forced convection, liquid cooling (optional)

Power Supply Fans

92 mm x 92 mm x 25 mm 2-wire (non-serviceable)

CPU Heatsink Fan(s)

Mainstream (<=95W): 80 mm x 80 mm x 15 mm 5-wire PWM
Performance (>95W): 92 mm x 92 mm x 25 mm 5-wire PWM

Chassis Fans

92 mm x 92mm x 25 mm 4-wire PWM

Memory Fans

No

Insight Diagnostics

HP Insight Diagnostics Offline Edition
The diagnostics utility enables you to perform testing and to view critical computer hardware and
software configuration information from various sources. This utility enables you to:

Run diagnostics
iew the hardware configuration of the system

Key features and benefits
HP Insight Diagnostics simplifies the process of effectively identifying, diagnosing, and isolating the
hardware issues. In addition to robust management tools, service tools can be invaluable in quickly
resolving system problems. To streamline the service process and resolve problems quickly, it is necessary
to have the right information available at the time that a service call is placed. The primary information
requirement, which is also the one that provides the greatest insight into potential system issues, is the
configuration of the system. Insight Diagnostics helps provide higher system availability. Typical uses of
the Insight Diagnostics are:

Testing and diagnosing apparent hardware failures
Documenting system configurations for upgrade planning, standardization, inventory tracking,
disaster recovery, and maintenance
Sending configuration information to another location for more in-depth analysis

Access Panel Key Lock No

ACPI-Ready Hardware Advanced Configuration and Power Management Interface (ACPI).

Allows the system to wake from a low power mode.
Controls system power consumption, making it possible to place individual cards and peripherals
in a low-power or powered-off state without affecting other elements of the system

Trusted Platform Module
Chip with optional
ProtectTools Software

Yes, Infineon SLB9635TT1.2

Integrated Chassis
Handles

No