A. Design, Installation & Location Considerations

1. Appliance Location

Consideration must be given to safety, convenience, traffic

flow, and the fact that the appliance will need a chimney and

chimney connector. It is a good idea to plan your installation

on paper, using exact measurements for clearances and

floor protection, before actually beginning the installation.
Maintain specified vent clearance to combustible

requirements listed by the vent manufacturers instructions

and all clearance to combustibles listed in this manual.
Check with your local building code agency before you begin

your installation. Be sure local codes do not supersede UL

specifications and always obtain the required permit so

that insurance protection benefits cannot be unexpectedly

cancelled. If any assistance is required during installation,

please contact your dealer.
We recommend that a qualified building inspector and your

insurance company representative review your plans before

and after the installation.
2. Room Sensor Location

The room sensor's location will have some effect on the

appliance's operation. When the sensor is located close to

the appliance, it may require a higher setting to keep the

rest of the house comfortable. If the sensor is located in

an adjacent room, or farther away from the stove, you will

notice higher temperatures near the appliance.

B. Fire Safety

Maintain the designated clearances to combustibles.

Insulation must not touch the chimney. You must maintain

the designated air space around the chimney. This space

around a chimney is necessary to allow natural heat

removal from the area. Insulation in this space will cause a

heat buildup, which may ignite wood framing.
NOTE: Clearances may only be reduced by means

approved by the regulatory authority having jurisdiction.
To provide reasonable fire safety, the following should be

given serious consideration:
• Install at least one smoke detector on each floor of

your home. Detectors should be located away from

the heating appliance and close to sleeping areas.

Follow the smoke detector manufacturer's placement

and installation instructions, and be sure to maintain

regularly.

• A conveniently located Class A fire extinguisher to

contend with small fires resulting from burning embers.

• A practiced evacuation plan, consisting of at least two

escape routes.

• A plan to deal with a hopper fire as follows:

In the event of a hopper fire:

a. Evacuate the house immediately.
b. Notify Fire Department.

Fire Hazard
• Do not operate appliance before

reading and understanding the

operating instructions.

• Failure to operate properly may

cause a house fire.

3

Getting Started

CAUTION

!

• Do NOT connect this unit to a chimney flue servicing

another appliance.

• Do NOT connect to any forced air distribution duct or

system.

CAUTION

!