beautypg.com

Mobile home, Caution, Caution warning – Harman Stove Company HARMAN Super Magnum Coal Stoker Stove User Manual

Page 15: Warning

background image

15

Do Not Burn Wet Coal!

Super-Magnum Coal Stoker Stove

3-90-02702R6_03/13

6

Mobile Home

A. Mobile Home Installation

Mobile home approval - U.S. only.
1. An outside air inlet must be provided for combustion

air, and must remain clear of leaves, debris, ice, and/or

snow. The outside air path must be unrestricted while the

appliance is in operation.

2. The combustion air intake system must be of metal

construction. It must permit zero-clearance to combustible

materials, and contain a rodent screen.

3. The appliance must be secured to the mobile home

structure by bolting it to the floor. There are brackets

included, you'll need to secure with the proper length lag

bolts.

4. The appliance must be grounded to the metal framing of

the mobile home

5. All clearances to combustibles and floor protection

requirements must be followed.

6. Follow the vent manufacturer's instructions when

installing in a mobile home.

7. Installation shall be in accordance with the Manufactured

Home and Safety Standard (HUD) CFR 3280, Part 24

8. The appliance must never be installed in a room

designated for sleeping.

This diagram shows the bracket that was used to bolt the

stove to the pallet. Use at least two of these brackets for

securing the appliance through the floor in a mobile home

installation. The bracket will slip over the top of the leveling

adjuster. The installer will need to determine and obtain the

properly sized lag bolts.

Installation must comply with Manufactured Home and

Safety Standard (HUD), CFR 3280, Part 24.

Never install in a room intended for sleeping.

Maintain structural integrity of mobile home:

• Floor, wall, ceiling and/or roof.

Do

NOT cut through:

• Floor joist, wall studs, or ceiling trusses.

• Any supporting material that would affect the

structural integrity.

CAUTION

Never draw outside combustion air from:

• Wall, floor or ceiling cavity.

• Enclosed space such as an attic or garage

CAUTION

WARNING

!

WARNING

!