1x x x x, Option tables by configuration, Replacement parts – Hubbell Type D6 User Manual
Page 9: 14a-9
14A-9
SEPTEMBER 2007
HUBBELL / CHANCE COMPANY – CENTRALIA, MISSOURI
®
®
POWER SYSTEMS, INC.
Type AR (Automation-Ready) Switch
Catalog Numbering System
Crossarm/Inter-
Phase Shaft
S
= Steel
F
= Fiberglass
M
= Steel crossarm,
fiberglass
interphase shaft
A
Position 1:
Position 2:
Insulation, kV Impulse
(maximum system kV)
1 = 110 porcelain (17.1kV)
3 = 110 polymer (17.1kV)
4 = 150 polymer (29kV)
6 = 150 polymer
(38kV grounded-wye)
7 = 150 polymer Long Leak (39.6")
(38kV grounded-wye)
R
Configuration
1
= Horizontal
2
= Vertical
3
= Ø-over-Ø
4
= Delta
5 = Inverted
Position 4:
Positions 5 through 12:
See Option Tables for each Configuration
X X X
X X
X
X
X
Option Tables by Configuration
Vertical Switch, S & F Controls
B
= Sensor Brackets
* C
= Control Insulator
H
= Captive Hardware
L
= Surge Arrester Brackets
* P
= Extra Pipe
* PP
= Two Extra Pipes
†
T
= Terminal Connectors (ATC 1343)
1
X X
X
X
U.S. Patents 6,207,919;
6,215,082; 6,281,460;
6,409,135; 6,459,053;
6,541,717; 6,818,846;
6,946,607.
Position 3:
*Options C, P, R, PP and RR do not apply
when Hook Stick Operated Control is supplied.
†
Options H and T, Captive Hardware and Terminal Con-
nectors, cannot be ordered together.
14.4kV, 25kV or 34.5kV 900 Amperes Continuous/Interrupt
Vertical Switch, T & G Controls
B
= Sensor Brackets
* D
= Control Insulator
H
= Captive Hardware
L
= Surge Arrester Brackets
* R
= Extra Pipe
* RR
= Two Extra Pipes
†
T
= Terminal Connectors (ATC 1343)
Replacement Parts
C8180001
Interrupter for all Mounting Configurations
E8181000P
Live Parts for all kV Ratiings and Mounting Configurations
Standard Controls — Pipe sizes
on drawings, pages 14A-4 thru -8
(All configurations)
S
= All Steel Vertical Sections
F
= One Fiberglass Vertical Section
H
= Vertical Controls replaced
with Hook stick Operating
Mechanism
Heavy-Duty Controls — 1
1
⁄
4
" IPS
(Vertical and Ø-over-Ø only)
T
= All Steel Vertical Sections
G
= One Fiberglass Vertical Section
Horizontal and Inverted Switches
B
= Sensor Brackets
* C
= Control Insulator
†
H
= Captive Hardware
L
= Surge Arrester Brackets
* P
= Extra Pipe
* PP
= Two Extra Pipes
S
= Steel Crossarm Brace, only one supplied
†
T
= Terminal Connectors (ATC 1343)
W
= Wood Crossarm Brace, only one supplied
X
= Extension Links
Phase-over-Phase Switch, S & F Controls
B
= Sensor Brackets
* C
= Control Insulator
†
H
= Captive Hardware
L
= Surge Arrester Brackets
* P
= Extra Pipe
* PP
= Two Extra Pipes
†
T
= Terminal Connectors (ATC 1343)
X
= Extension Links
Phase-over-Phase Switch, S & F Controls
B
= Sensor Brackets
* C
= Control Insulator
†
H
= Captive Hardware
L
= Surge Arrester Brackets
* R
= Extra Pipe
* RR
= Two Extra Pipes
†
T
= Terminal Connectors (ATC 1343)
X
= Extension Links
Delta Switch
B
= Sensor Brackets
* C
=
Control Insulator
†
H
=
Captive Hardware
L
=
Surge
Arrester Brackets
* P
= Extra Pipe
* PP
= Two Extra Pipes
†
T
=
Terminal Connectors (ATC 1343)
X
= Extension Links