Power

ProLiant DL165 G7 Fully Configured

115V/60Hz

220V/50Hz

Fully Loaded System Input Wattage (W)

568

556

Fully Loaded System Input Current (A rms)

4.99

2.58

Fully Loaded System Thermal (BTU- Hr)

1939.15

1898.18

Fully Loaded System VA (Volt-Amp)

574

567

System Inrush Current with all power supplies
loaded (A)

30

30

Power cord requirements

Nema 5-15P to IEC320-
C13

IEC320-C13 to IEC320-C14

NOTE: Power shown is for a fully configured system consisting of (2) CPU, (8) double-sided DIMMs, (2) HDDs, (1) CD-
ROM, and (2) PCI cards.

Power Cord

AF556A

Server Power Cords

One 6' Highline (IEC-IEC) power cord ships standard

NOTE: HP ProLiant DL servers no longer ship standard with NEMA
power cords (163719-002) that allow connection to 110V US wall
outlets in a home or office. ProLiant DL servers are primarily
connected to PDU's in data center racks so they now ship standard
with only a PDU power cord (416151-B21). If a user wishes to power
a ProLiant DL server using a 110V receptacle (NEMA-15), the NEMA
power cord (227099-001) must be ordered separately.

If customers require a local power cord, they can check the power
cord matrix for the appropriate cord. Please see the following power
cord matrix:

http://www.hp.com/go/powercordmatrix

.