Ac performance, 61, Capacitance, 61, Dc performance, 61 – HP E1367A User Manual
Page 61: Input characteristics, 61, Insulation resistance, 61, Interrupt level, 61, Power requirements, 61, Relay life, 61, A. hp e1366a/e1367a rf multiplexer specifications, Appendix a

Appendix A
HP E1366A/E1367A RF Multiplexer
Specifications
Input Characteristics
Maximum Voltage - any center or shield
to any other center, shield, or chassis:
42 V Peak
Maximum Current per Channel or
Common:
1 Adc or ac
rms
Maximum Power per Channel or
Common:
24 W or 24 VA
General
Channels consist of non-latching
armature relays.
Typical Relay Life:
With no load: 5 x 10
6
operations
With max. rated load: 10
5
operations
Note: Relays are subject to normal wearout
based on the number of operations.
DC Performance
Thermal Offset:
<6
µ
V
Typical Closed Channel Resistance:
<1
Ω
End of Relay Life Closed Channel
Resistance:
<3
Ω
Insulation Resistance
(any terminal to any terminal):
≤
(40
°
C, 65% RH): >10
8
Ω
AC Performance
For Z
L
= Z
S
= 50
Ω
(E1366A)
For Z
L
= Z
S
= 75
Ω
(E1367A)
<10MHz <100MHz <500MHz <1.3GHz
Insertion Loss (dB)
≤
(40
°
C, 65% RH)
<0.3
<0.7
<1.5
<3.0
Crosstalk(dB) (Channel-Channel*, or Channel-Common)
1
<-90
<-80
<-60
<-40
VSWR
<1.2
<1.25
<1.35
<1.55
* With one channel closed.
1 Specification assumes 50
Ω
or 75
Ω
termination. If all channels
unterminated, derate specification by 6dB.
Risetime:
<300psec
Signal Delay:
<3nsec
±
50psec
Capacitance:
Center-shield <60pF
Chassis-shield <0.15
µ
F
Module Size/Device Type:
B, register-based
Connectors Used:
P1
Number of Slots:
1
VXIbus Interface Capability:
Slave, Interrupter, A16, D16
Interrupt Level:
1-7, selectable
Power Requirements:
Voltage +5 +12
Peak module current, IPM (A): 0.10 0.18
Dynamic module current, IDM (A): 0.01 0.01
Watts/Slot:
3.0
Appendix A
HP E1366A/E1367A RF Multiplexer Specifications 61