Scanning Channels

Comments

Scan List Can Extend Across Boundaries. For multiple-multiplexer
switchbox instruments, the scan list can extend across multiplexer
boundaries. For example, for a two-multiplexer switchbox instrument,

SCAN (@100:213)

will scan all channels in both multiplexers.

Setting Multiple/Continuous Scans. Use

ARM:COUN <

number

>

to set

from 1 to 32767 scans through the scan list. Use

INIT:CONT ON

to set

continuous scanning. See Chapter 4.