Addressing the registers 66, Reading the registers 66, Id/device type registers 66 – HP E1367A User Manual
Page 66: Status/control register 66, Channel enable registers 66, Registers, 66, Reading registers, 66, Register types, 66, Channel enable registers, 66, Device type registers, 66

Addressing the Registers
To read or write to specific registers, you must use the register address.
Since the addresses for HP 75000 Series B or Series C plug-in modules are
A00 through A15, use the VME A16 mnemonic for the address space. The
address space within the mainframe/command module memory map
depends on the mainframe/command module used. For example, the address
of the HP E1300A/E1301A Mainframe starts at 1F0000
h
.
For the HP E1300/E1301, the A16 space is divided so modules are
addressed only at locations beginning with C000
h
within A16. Each
module is allocated 64 register addresses (40
h
). The module base address is
related to the logical address set by the logical address switch (LADDR) on
the module:
base address (
h
) = (logical address
h
)*40
h +
C000
h
For the RF multiplexers, the factory-set logical address is 120 (78
h
), so the
base address = (78
h
)*(40
h
) + C000
h
= DE00
h
. Then, for example, to address
the Status/Control register of an RF multiplexer in an HP E1300A/E1301A,
the register address = [A16 location]
h
+ [base address]
h
+ [register offset]
h
= 1F0000
h
+ DE00
h
+ 04
h
= 1FDE04
h
.
Reading the Registers
You can read the following RF multiplexer registers:
•
ID register (base + 00
h
)
•
Device Type register (base + 02
h
)
•
Status/Control register (base + 04
h
)
•
Bank 0 Channel Enable register (base + 08
h
)
•
Bank 1 Channel Enable register (base + A
h
)
ID/Device Type
Registers
For either RF multiplexer, a read of the ID register (address base + 00
h
)
returns FFFF
h
since the multiplexers are manufactured by Hewlett-Packard
and are A16 only, register-based devices. The Device Type register (base +
02
h
) returns FF80
h
for the HP E1366A (50
Ω
) multiplexer and returns FF84
h
for the HP E1367A (75
Ω
) multiplexer.
Status/Control
Register
Each relay requires about 15 msec execution time (close to open or open to
close) during which time the RF multiplexers are “busy” . A read of the
Status/Control register (base + 04
h
) returns FFFF
h
when the module is not
busy or returns FF7F
h
(bit 7 is low-true) when the module is busy.
Channel Enable
Registers
A read of either of the two Channel Enable registers (base + 08
h
for bank 0
or base + A
h
for bank 1) always returns FFFF
h
, regardless of the channel
states.
66 HP E1366A/E1367A Multiplexer Registers