D. blower, E. control module operation – Heat & Glo Fireplace Heat & Glo 350TRSILP-AUF User Manual

Page 55

background image

55

Heat & Glo • 350TRSI-AUF, 350TRSILP-AUF • 2089-980 Rev. R • 2 /13

BLUE

BROWN

GREEN/

YELLOW

Figure 12.2

D. Blower

These heaters have a factory installed fan and electrical

junction cord. These components are located behind the

lower door.
Use of the fan requires that the Junction cord (factory in-

stalled) be connected to 220/240 VAC service before per-

manently enclosing the heater. The service cord is found

on the right exterior side of the unit. See Figure 12.2 for

wire connection detail.

E. Control Module Operation

1. The control module has an ON/OFF/REMOTE selector

switch that must be set. See Figure 12.3.

OFF Position: Appliance will ignore all power inputs and

will not respond to any commands from a wall switch or

remote. The unit should be in the OFF position during

installation, service, battery installation, fuel conversion,

and in the event that the control goes into LOCK-OUT

mode as a result of an error code.

ON Position: Appliance will ignite and run continuously

in the HI flame setting, with no adjustment in flame

output. This mode of operation is primarily used for

initial installation or power outage operation with battery

backup.

REMOTE Position: Appliance will initiate commands

from an optional wired wall switch and/or the wireless

remote (RC300AU).

2. If using a wired wall switch with the module in REMOTE

mode, the flame output can be adjusted with the HI/

LO selector switch on the module. See Figure 12.3.

Note that the flame HI/LO selector switch will become

inactive once an optional remote control (RC300AU)

is programmed to the control module. Note that the

control module will always ignite the fireplace on HI

and remain so for the initial 10 seconds of operation.

If the HI/LO is switched to the LO position, the flame

output will automatically drop to the lowest setting after

the flame has been established for 10 sec. After this

10 second period, the flame can be adjusted from HI

to LO with the switch.

3. The control module has safety feature that automatically

shuts down the fireplace after 9 hours of continuous

operation without receiving a command from the

RC300AU remote.

4. If you intend to use both an optional wired wall switch

and the RC300AU remote control to operate your

fireplace, the wall switch will override any commands

given by the remote.

5. The module has the capability to recognize potential

malfunctions. If these occur, it will fail to ignite and/or

respond to a command to ignite via the wall switch and/

or remote. In this case, the module may have gone

into LOCK-OUT mode. In this state, it will emit a RED/

GREEN LED error code. To reset the error code, switch

the selector to OFF, and then back to REMOTE or ON.

If the ignition command again fails, the module will emit

an LED error code, prior to going back into LOCK-OUT

mode. Contact your dealer for service if this occurs.

Note: If the module is in LOCK-OUT mode, resetting the

circuit breaker to the appliance will also reset the module.

Note: For units installed in Australia, the residence’s 220/240

wall outlet to which this appliance’s power cord is connected,

must be wired to an in-line on/off switch. This is required for

servicing and/or resetting the control module in the event of

a control module LOCK-OUT.

Figure 12.3 Control Module

NG/LP SETTING

STATUS INDICATOR LED

SELECTOR

SWITCH

FLAME HI/LO SWITCH

240V BLOWER

JUNCTION CORD

AUX 300 CE

GROUND TERMINAL TO

FIREPLACE CHASSIS