Rear vent - vertical termination one elbow, Two elbows – Heat & Glo Fireplace Heat & Glo 350TRSILP-AUF User Manual
Page 36
![background image](/manuals/93439/36/background.png)
Heat & Glo • 350TRSI-AUF, 350TRSILP-AUF • 2089-980 Rev. R • 2/13
36
Rear Vent - Vertical Termination
One Elbow
Figure 7.16
Two Elbows
Figure 7.17
V
1
H
1
INSTALLED
HORIZONTALLY
H
1
H
2
V
1
USE DVP SERIES COMPONENTS ONLY
USE DVP SERIES COMPONENTS ONLY
V
1
Minimum
H
1
Maximum
1 ft.
305 mm
3 ft.
914 mm
2 ft.
610 mm
6 ft.
1.83 m
3 ft.
914 mm
8 ft.
2.44 m
4 ft.
1.22 m
11 ft.
3.35 m
5 ft.
1.52 m
12 ft.
3.66 m
V
1
+ H
1
= 36 ft. (10.97 m) Maximum
H
1
= 12 ft. (3.66 m) Maximum
V
1
Minimum
H
1
+ H
2
Maximum
2 ft.
610 mm
Back to Back 90º Elbows
1 ft.
310 mm
3 ft.
915 mm
2 ft.
610 mm
4 ft.
1.22 m
3 ft.
914 mm
8 ft.
2.44 m
4 ft.
1.22 m
10 ft.
3.05 m
V
1
+ H
1
= 32 ft. (9.75 m) Maximum
H
1
+ H
2
= 9 ft. (2.74 m) Maximum