beautypg.com

HP StudioJet User Manual

Page 53

background image

55

Chapter 5: Troubleshooting

Jagged scan alignment.

Cause:

1. Motion alignment is incorrect.

2. Platen or stand is not level.

3. Loose carriage pulley causing ran-

dom/uneven gaps between scans.

Solution:

1. Use the Control Center to ad-

just motion alignment as shown

in the Routine Maintenance

chapter.

2. Follow the directions in the

FlexJet E Printer or StudioJet

Quick Start Guide to level the

stand and platen.

3. Contact Ioline customer service.

Poor paper tracking.

Cause:

1. Paper is improperly loaded.

2. Bad paper roll or paper quality.

3. Pinchwheels not in correct

location.

4

Feed paper roll is centered on

feed shaft.

5. Paper roll not centered on feed

shaft.

6. Loose paper hubs.

Solution:

1. Reload and align paper.

2. Replace the paper roll.

3. Reposition the pinchwheels

as indicated in the Operation

chapter.

4. Center the paper roll on feed shaft

(see Figure 16). Make sure screws

are tight on both paper hubs.

5. Ensure the feed roll is centered

on the feed shaft.

6. Tighten screws on the paper hubs.

Gap between each scan.

Cause:

1. Frame Gap setting is incorrect.

2. Ink cartridge is out of ink, dirty

or the print head is plugged.

Solution:

1. Use the

Control Center to

adjust frame gap as shown in the

Routine Maintenance chapter.

2. Check ink level indicator.

Replace cartridge if indicator is

black. If cartridge is not empty,

see Cartridge Maintenance

and Handling under the Rou-

tine Maintenance chapter.

Pauses during printing.

Cause:

1. Vector density is very high due

to fine detail or the design soft-

ware is not using fonts embed-

ded in the printer.

2. Communication baud rate is set

very low.

Solution:

1. Reduce vector density, use em-

bedded printer fonts, or increase

communication baud rate.

2. Increase baud rate from the

minimum of 9600 baud to the

default of 38,400 or higher.