Ioline FlexJet E User Guide
Reset Calibration Values
Perform the steps below if calibration values have been altered:
1.
With the printer in STOP mode, use the arrow keys to move
the carriage to the center of the traverse.
2.
Turn power off on the printer.
3.
Copy the factory calibration values from the white sticker
inside the service station (see Figure 35.) If no sticker is present,
recalibrate the machine using the procedure available in this
User Guide.
4.
Press and hold the Unroll key on the keypad then turn printer
power on.
5.
When the OK light turns red, release the key.
6.
Use the Control Center software to re-enter the calibration
values copied from the sticker OR perform the calibration using
the directions in this chapter.
7.
Turn power off then back on to ensure the new calibration val-
ues take affect. Perform test plots to verify proper calibration
and operation.
8.
If you have any difficulties, please contact Ioline Customer
Service.
Figure 35. Factory calibration values on the sticker under the right end cover.