Appendix a - specifications – Home Automation SECURITY SYSTEM User Manual
Page 76
APPENDIX A - SPECIFICATIONS
Size:
Controller: 9.1W x 12.1H x 3.5D
Console:
4.6W x 4.5H x 1.2D
Weight:
Controller: approx. 4.5 lb.
Console:
approx. 0.5 lb.
Operating
32 - 122 degrees F (0 - 50 degrees C)
Ranges:
10 - 95 % relative humidity, non-condensing
Power:
120 VAC, 60 Hz, 60 watts
Transformer:
16.5 VAC, 40 VA, 50/60 Hz
Battery:
Sealed
Rechargeable
Lead-Acid,
12
volts
Bell Fuse:
Polyfuse: 1.35 A
Device Fuse:
Polyfuse: .9 A
Output Fuse:
Polyfuse: .3 A
Battery Fuse:
Polyfuse: 2.5 A
Polyfuses are permanent fuses that do not need replacement.
Nominal Output Voltage: 10-13.8 VDC
Low Voltage Cut Out:
approx. 9 VDC
Typical Current Consumption at Nominal Voltage:
Controller:
105
mA
Console:
backlight off, 35 mA
backlight on, 100 mA
CONTROLLER OUTPUTS
UL RATINGS
MAXIMUM
Devices: AUX 12 VDC, CONSOLE, and OUTPUTS 1 and 2:
200 mA
500 mA
Bell:
BELL
350
mA
1
A
Outputs: OUTPUTS 1 and 2, each, maximum:
100 mA
100 mA
Backup:
Required
battery
backup
hours:
24
hours
Battery:
Recommended
Battery:
7
Ah
14
Ah
72