beautypg.com

Exit delay, Audible exit delay, Entry/exit chime – Home Automation SECURITY SYSTEM User Manual

Page 66: Perimeter chime, Enable quick arm, Enable auto bypass, All on for alarm, Beep on trouble

background image


Exit Delay

The Exit Delay is the time, in seconds, that you have to leave your house when you turn on the system. When arming the system
in Day, Night, or Away modes, the system will wait this amount of time before arming.

The default exit delay is 15 seconds. You may change it from 15 to 180 seconds.

EXIT DELAY: 15

15-180 SECONDS


Audible Exit Delay

The Audible Exit Delay is an audible indication from the console beeper while the exit delay is in effect. During the last 10
seconds of the exit delay, the audible indication will beep twice as fast to let you know that you must leave at once.

The default setting for Audible Exit Delay is Yes.

Entry/Exit Chime

When Entry/Exit Chime is set to Yes, the console(s) will beep once when a door on an entry/exit zone is opened, even if the alarm
system is off. This lets you know when someone enters and leaves.

The default setting for Entry/Exit Chime is Yes.

Perimeter Chime

When Perimeter Chime is set to Yes, the console(s) will beep once when a window or any other perimeter zone is opened, even if
the alarm system is off.

The default setting for Perimeter Chime is Yes.

Enable Quick Arm

The Quick Arm feature allows the security system to be armed by pressing the desired mode key twice instead of having to enter
your code.

The default setting for Enable Quick Arm is No.

Enable Auto Bypass

The Auto-Bypass feature allows the system to automatically bypass an open zone when the system is armed, rather than setting
off the alarm. In some applications, it may be preferable to allow arming only if all zones are secure (READY).

With Auto-Bypass Off, all zones to be armed must be secure when the system is armed. Otherwise, the console will beep three
times and display "ZONE NOT RDY". If the system is armed and a zone is open when the Exit Delay expires, the alarm will
sound.

All On For Alarm

This option will instruct OmniLT to execute an X-10 All On command in the event that any type of alarm occurs.

Beep On Trouble

If the OmniLT detects any troubles with itself or one of the zones connected to it, it will display a message on the screen and beep
the console twice per second, continuously (i.e. beep beep...beep beep...). You can silence this sound by pressing the ' * ' key.
However, if the trouble occurs again, the beeper will start beeping again.

If you do not wish to hear the beeping sound when trouble occurs, set Beep On Trouble to No.

The default setting for Beep On Trouble is Yes.

62