31

2-4. CSR related to other functions
(1)

FLASH

(CSR:

F200

0018

h)

Adjusts flash signal timing for mode 0 trigger operation.
-OFF-

Setting value 80000000h
Flash signal output absent.

-Manual adjustment-

Setting value 8200xyyy h x: 0-NARROW, 1- MIDDLE, 2- WIDE (pulse width)

yyy: 000h to FFFh ( START)

See flash signal pulse width and timing chart on page 41.


(2)

BAR

(CSR:

F200

00DC

h)

Set to ON for Color Bars.

-OFF-

Setting value 80000000 h

-ON-

Setting value 82000000 h


(3)

NEGA (CSR:

F200

00E0

h)

On setting produces negative image.
-OFF-

Setting value 80000000 h