beautypg.com

Hitachi HV-F31F User Manual

Page 32

background image

18

-Manual adjustment-

Setting value 8x0y0000 h

x:2- LOW ACTIVE, 3- HIGH ACTIVE
y:0- MDOE0, 1- MODE1

Trigger mode polarity is switched at external signal values x and y.
See trigger operation details and timing chart (page 39).


(10)

INITIALIZE

(CSR:

F0F0

0000

h)

Return equipment to status at time of release from factory.

-Initialization-

Setting value 80000000 h


(11) MEMORY SAVE (EXECUTE)

(CSR: F0F0 0618 h)

Make back up of presently effective memory channels.

-BACK UP execute-

Setting value 80000000 h

(12) MEMORY SAVE (Ch SET)

(CSR: F0F0 0620 h)

Select channel carried out memory backup.

-channel set-

Setting value x0000000 h

x: 1- ch1, 2- ch2, 3- ch3, 4- ch4


(13) CURRENT MEMORY

(CSR: F0F0 0624 h)

Loading memory channel designating data

-LOAD BACK UP-

Setting value x0000000 h

x: 0- FACTORY SETUP, 1- ch1, 2- ch2, 3- ch3, 4- ch4

This manual is related to the following products: