Case 4 — boot process fails, Error message utility (emu) – HP KAYAK XU800 User Manual
Page 16

Your PC Workstation Does Not Start Correctly
Case 4 — Boot Process Fails
16
Case 4 — Boot Process Fails
When the power button is pressed, the PC Workstation starts to boot
and there is activity on the monitor, but the boot process then fails with
an error message. Status LED flashes red. A configuration error has
been detected.
•
Boot process fails with an error message.
•
Status LED flashes
RED
.
•
Beep code emitted.
•
MaxiLife status panel displays
and a POST error message.
NOTE
Before removing the cover, switch off the display and PC Workstation by pressing the
power-off button for five or six seconds. Disconnect the power cord and any accessory
cables. When checks have been completed, close the PC Workstation and reconnect
the power cord and accessory cables. Verify that the PC Workstation boots correctly.
Error Message Utility (EMU)
In the event of an error generated in POST (Power-On-Self-Test)
during the boot process, there are two beeps, then the Error Setup
Manager gives access to one or more detected errors. For each error, a
specific message is displayed on the monitor screen.
NOTE
If the monitor is not available, a short error message is also displayed on the MaxiLife
LCD panel.
EMU is accessed by pressing ENTER. A detailed description of the
reason for the failure and how to solve the problem is displayed. All
errors detected by the POST have an associated EMU message. The
following examples give the different types of error categories.
Category #1:
If an error can be bypassed with
ERROR
0070
CPU Terminator Card Error
Press