5-6. Serial Number And Rating Label Location
The serial number and rating information for this product is located on back. Use rating label to determine input power requirements and/or rated output.
For future reference, write serial number in space provided on back cover of this manual.
5-7. Selecting A Location And Connecting 115 Volt Input Power
!
Installation must meet all
National and Local Codes −
have only qualified persons
make this installation.
!
Special installation may be
required where gasoline or
volatile liquids are present −
see NEC Article 511 or CEC
Section 20.
1
Grounded Receptacle −
NEMA Type 5−15R
(Customer Supplied)
For 115 volt AC input power, a 20
ampere individual branch circuit
protected by time-delay fuses or
circuit breaker is required.
2
Plug From Unit
Select extension cord of 12 AWG
for up to 50 ft (15 m) or 10 AWG for
50 up to 100 ft (30 m).
803 443-C
!
Do not move or operate unit
where it could tip.
18 in.
(460 mm)
18 in.
(460 mm)
1
2