Henny Penny 342 User Manual
Page 8
Model OFE/OFG/OEA/OGA-341, 342
2-8. FLAME SENSOR/
PILOT / IGNITOR
ASSEMBLY (Gas)
(Continued)
2. Remove the control panel and heat shield from control area.
Figure
2-19.
Figure 2-19
3. Disconnect the flame sense wire from ignition module.
Figure
2-20.
Figure 2-20
4. Using a 7/16” wrench, loosen the nut on the pilot tube and pull
tube from assembly. Figure 2-21.
Figure
2-21
5. Remove the two screws securing the assembly and pull
assembly from unit. Figure 2-22.
6. Now the flame sensor or or pilot assembly can be removed
from
bracket.
Figure
2-22
2-8
1003
See also other documents in the category Henny Penny Fryers:
- 590 (25 pages)
- OEA/OGA-342 (1 page)
- COMPUTRON 8000 (1 page)
- OEA/OGA-321 (78 pages)
- OFG-390 (2 pages)
- OEA/OGA-322 (1 page)
- none (12 pages)
- OFE-321 (46 pages)
- CLIMAPLUS LCS (84 pages)
- PFE-590 (80 pages)
- OFG-322 (1 page)
- OEA/OGA-324 (1 page)
- 690 (3 pages)
- 322 (11 pages)
- OFG-342 (2 pages)
- EVOLUTION ELITE EEG-144 (72 pages)
- 691 (1 page)
- OFE/OFG-323 (2 pages)
- FS-100 (2 pages)
- 680 (2 pages)
- PFE- 590/592 (3 pages)
- FS-200 (9 pages)
- 290 (17 pages)
- OEA-322 (2 pages)
- FDS-100 (2 pages)
- PFG-600 Gas (2 pages)
- OFE-341 (8 pages)
- 291 (20 pages)
- OFE-322 (2 pages)
- OFE/OFG-324 (29 pages)
- ODG-323 gas (2 pages)
- OFE/OFG/OEA/OGA-341 (1 page)
- 500 (31 pages)
- EEE-144 (63 pages)
- OFG-391 (79 pages)
- FM03-681 (12 pages)
- G L O S S A R Y OFE- 290 (5 pages)
- PRESSURE FRYERS 600 (66 pages)
- 803 (1 page)
- OEA (22 pages)
- OFE-323 (2 pages)
- OFG-321 gas (2 pages)
- 341 (3 pages)
- FM07-020-F (40 pages)