Check the battery and cable terminals, Check the high pressure hoses, C 4.74 – Holder C-Trac 4.74 User Manual
Page 169: Operating instructions, Maintenance every 125 hours

C 4.74
Operating instructions
168
149 443
Maintenance every 125 hours
1
Bild_C246
Check the battery and cable terminals
CAUTION
When working on the electrical equipment,
always disconnect the ground lead (1) at the
battery.
-
Check the battery acid level and inspect the battery
for leaks. Observe the information of the battery
manufacturer.
-
Remove any corrosion on the battery terminals.
-
Grease the battery terminals with non-acidic battery
grease.
-
Check cables and cable ends for secure connection
and damage.
-
Replace any damaged cables and terminals.
Check the high pressure hoses
-
Check the high pressure hoses for cracks, bending
and chafing, and for porous surfaces.
Replace damaged high-pressure hoses immediately.
This work may only be carried out by an authorized work-
shop.