Page 17: Electrical requirements, Warning

background image

49-5000561 Rev. 2

INST

ALLA

TION INSTRUCTIONS

Installation Preparation

IMPORTANT ELECTRICAL
SAFETY—READ
CAREFULLY

WARNING

RISK OF ELECTRIC SHOCK.

‡$OOHOHFWULFDOFRQQHFWLRQVDQGZLULQJ0867EH

installed by a qualified electrician.

‡)ROORZWKH1DWLRQDO(OHFWULFDO&RGH1(&DQGRU

local codes and ordinances.

‡)RUSHUVRQDOVDIHW\WKLV=RQHOLQHXQLWDQGFDVH

must be properly grounded.

‡3URWHFWLYHGHYLFHVIXVHVRUFLUFXLWEUHDNHUV

DFFHSWDEOHIRU=RQHOLQHLQVWDOODWLRQVDUHVSHFLILHGRQ

the nameplate of each unit.

‡'RQRWXVHDQH[WHQVLRQFRUGZLWKWKLVXQLW

• Aluminum building wiring may present special

problems—consult a qualified electrician.

• When the unit is not running there is still voltage to

the electrical controls.

• Disconnect the power to the unit before servicing by:

5HPRYLQJWKHEUDQFKFLUFXLWIXVHVRUWXUQLQJWKH

circuit breakers off at the panel.

2.

Disconnect the power cord from the unit.

BEFORE YOU BEGIN

Read these instructions completely and carefully.

IMPORTANT –

Save these

instructions for local inspector’s use.

IMPORTANT –

Observe all governing

codes and ordinances.

Note to Installer –

Be sure to leave these

instructions with the owner.

Note to Owner –

.HHSWKHVHLQVWUXFWLRQVIRU

future reference.

Proper installation is the responsibility of the

LQVWDOOHU&RPSOHWHGLQVWDOODWLRQRIWKH=RQHOLQH

shall not be accessible to the general public.

Product failure due to improper installation is not

covered under the Warranty.

7HDPOLIWLVUHFRPPHQGHGZKHQPRYLQJXQLW

installation procedures as described in these
instructions when installing this air conditioner.

Questions? Call 844-GE4-PTAC (or 844-434-7822 ) or

Visit our Website at:

GEAppliances.com

ELECTRICAL
REQUIREMENTS

NOTE: All field wiring must comply with NEC and
local codes. It is the responsibility of the installer
to ensure that the electrical codes are met.

Wire Size

Use

ONLY

wire size recommended

for single outlet branch circuit

Fuse/Circuit
Breaker

8VH21/+9$&5FLUFXLWEUHDNHULQGLFWHG

on units rating plate. Proper over
current protection to the units is the
responsibility of the owner.

Grounding

8QLW0867EHJURXQGHGIURPEUDQFK

circuit to unit, or through separate
ground wire provided on permanently
connected units. Be sure that branch
circuit is grounded.

Wire Sizing

Use recommended wire size given
in tables and install a single branch
circuit. All wiring must comply with
local and national codes.

NOTE: Use copper conductors
only.

WARNING

RISK OF ELECTRIC SHOCK.

&DQFDXVHLQMXU\RUGHDWK7KLVDSSOLDQFHPXVWEH

properly grounded.

‡8VH21/

outlet branch circuit.

• Proper current protection is the responsibility

of the owner.

NOTE:

Use copper conductors only.

Recommended Branch Circuit Wire Sizes*

Nameplate

Maximum Circuit

Breaker Size

AWG Wire Size**

$

N NSURGXFWVRQO\

$

$

AWG - American Wire Gauge

6LQJOHFLUFXLWEUHDNHUIURPPDLQER[

** Based on copper wire, single insulated conductor

DW๦

C