Installation Preparation

Ductwork

Prepare the closet ductwork for later connection
to the case.

7KHGXFWV\VWHPVKRXOGEHGHVLJQHGIRUDPD[LPXP
IULFWLRQUDWHRI´ZDWHUFROXPQWDNLQJLQWR

consideration all fittings, registers and/or diffusers.

DO NOT operate unit without a supply duct
attached.

7KHUHWXUQDLUWRWKH=RQHOLQHXQLW0867127EH
GXFWHGDQGDOOXQLWV0867KDYHDIUHHUHWXUQDLU

configuration to perform properly.

7KHWRWDOIORZUDWH&)0DQGH[WHUQDOVWDWLFSUHVVXUH
(63DYDLODEOHFDQEHHVWLPDWHGIURPWKHFKDUWVRQ

this page. Use these charts to select your fan speed
setting.

7KHFROODURQWRSRIWKHXQLWDFFHSWVVWDQGDUG´
GXFW3XOODOOGXFWWLJKW([WUDGXFWVODFNFDQJUHDWO\

increase static pressure.

NOTICE:

Flex duct can collapse and cause

airflow restrictions. Do not use flex duct for 90°
bends or unsupported runs of 5 ft. or more.

Indoor Air Flow Data

,QGRRUDLUIORZPD\EHGHWHUPLQHGE\PHDVXULQJWKH
H[WHUQDOVWDWLFSUHVVXUH(63RIWKHGXFWV\VWHPDQG

then using the chart below to determine the actual
airflow.

Under no circumstances should the Zoneline

unit be operated to an ESP in excess of .3” W.C..

2SHUDWLRQRIWKH=RQHOLQHXQGHUWKLVFRQGLWLRQZLOOUHVXOW

in inadequate air flow thus leading to poor performance
and/or premature component failure.

Your airflow should be balanced based on many
factors, such as available ESP, room CFM, and

GXFWZRUN&RQVXOWDQ+9$&HQJLQHHUIRUSURSHU
DSSOLFDWLRQV([WHUQDOVWDWLFSUHVVXUH(63FDQEH

measured with a manometer or pitot tube. Once this
ESP is established, you can calculate the CFM using
the above chart.

INST

ALLA

TION INSTRUCTIONS

Indoor Air Flow Data (cont)

Higher CFMs tend to increase Sensible capacity,
enhance room circulation and increase duct noise,
while lower CFMs tend to increase Latent capacity
and reduce noise.

Indoor Fan CFM

Fan Boost Mode

ON

OFF

ESP

(in. water)

High

CFM

Medium

CFM

Medium

CFM

Low

CFM

0.1
0.15
0.2
0.25
0.3

468
435
409
392
352

408
371
351
306
239

408
371
351
306
239

305
272
198

*
*

0.1
0.15
0.2
0.25
0.3

468
435
409
392
352

408
371
351
306
239

408
371
351
306
239

356
328
288

220

*

0.1
0.15
0.2
0.25
0.3

468
435
409
392
352

417
380
359
318
253

417
380
359
318
253

376
345
314

250

*

AZ95E12

AZ95H12

* Do not operate unit in these conditions

AZ95(H/E)18

0.1
0.15
0.2
0.25
0.3

543
514
481
458
442

468
435
409
392
352

468
435
409
392
352

408
371
351

306
239

AZ95(H/E)09

NOTE: Values taken at 70-75°F ambient temperature

CFM Recommendations

AZ95(H/E)09

AZ95E12

AZ95H12

AZ95(H/E)18

305 408 468 356 408 468 376 417 468 408 468 543

• = Recommended Mid Range