LG Simple Remote Controller Thermostat Use and Care Guide User Manual

Page 8

background image

Setting the setback temperature

1 Press button for 3 seconds.

2 Press button to move the setback

mode.

3 Press button to select cool/heat tem-

perature.

4 Press button to change the tempera-

ture.

5 Press button to set temperature.

6 Press button for 3 seconds.

Setting the override time

1 Press button for 3 seconds.

2 Press button to move the override

mode.

3 Press button to select override time.

4 Press button to set override time.

5 Press button for 3 seconds.

h

You can set in units of 30 minutes.

OPERATION INSTRUCTIONS - Sub function

15

ENGLISH

14

OPERATION INSTRUCTIONS - Sub function

ENGLISH

Example of using change temperature

Condition

1) Mode: Auto mode

2) Temperature: 72°F(22°C)

3) Change Temperature: 6°F(3°C)

Change

Temperature 6°F(3°C) difference

h

In case of the above conditions, it operates
as in the graph.

This function sets the minimum difference be-
tween heating and cooling set points.

h

This function is used in connection with the
dual set points control product.

1

Press button for 3 seconds.

2

Press button to move the dead band

mode.

3

Press button to change the dead band

temperature. (0 ~ 10°F/0 ~ 5°C)

4

Press button to set temperature.

5

Press button for 3 seconds.

h

This function may not work in some prod-

ucts.

: Cooling operation start

: Heating operation start

ڸ

ڸ

ڹ

Temp(°F/°C)

78°F(25°C)

72°F(22°C)

66°F(19°C)

Change temperature is the function to setup
air-cooling and heating drive automatically
changeable according to the temperature at
single set point auto operation mode.

h

This function is used in connection with the
single set point control product.

1

Press button for 3 seconds.

2

Press button to move the change tem-

perature setting mode.

3

Press button to change the tempera-

ture. (2 ~ 14°F/1 ~ 7°C)

4

Press button to set temperature.

5

Press button for 3 seconds.

Change temperature setting
(Single set point)

Dead band (Dual set points)

Press the button for 3 seconds. You can

enter to sub function setting mode and press

the button repeatedly to change the sub

function mode in the following order.

h

Some functions may not operate depending
on the product.

h

Dead band setting – When it connects with
an dual set points control product.
Change temperature – When it connect
with single set point control product.

Setback temperature

setting

Override time

setting

Dead band setting or

Change temperature

setting

Vane angle control

WLAN module

access

point mode

Heater

1,MFL62862020,영영 2018. 1. 3. 영영 1:01 Page 14