Power Supply Cord Strain Relief:

Power Supply Cord Connection

1.

Attach power supply cord strain relief

D

C

B

A

Remove the screws from a 3/4" (19 mm) UL Listed strain

relief (UL marking on strain relief). Put the tabs of the two

clamp sections (C) into the hole below the terminal block

opening (B) so that one tab is pointing up (A) and the other

is pointing down (D), and hold in place. Tighten strain relief

screws just enough to hold the two clamp sections (C)

together.

4-Wire Power Supply Cord Connection

IMPORTANT:

A 4-wire connection is required for mobile homes

and where local codes do not permit the use of 3-wire connections.

4-wire receptacle

(NEMA type 14-30R)

4 prong plug

Spade terminals with

upturned ends

Ring terminals

2.

Attach power supply cord

to strain relief

Put power supply cord through the strain relief. Be sure that

the wire insulation on the power supply cord is inside the

strain relief. The strain relief should have a tight fit with the

dryer cabinet and be in a horizontal position. Do not further

tighten strain relief screws at this point.

Power supply cord 4-wire receptacle

(NEMA Type 14-30R):

Go to “4-Wire Power Supply Cord

Connection.”

Power supply cord 3-wire receptacle

(NEMA Type 10-30R):

Go to “3-Wire Power Supply Cord

Connection.”

If your outlet looks like this: