beautypg.com

Install leveling legs, Electrical installation – u.s.a. only, Choose electrical connection type – Whirlpool 27 Inch Ventless Electric Dryer Installation Instructions User Manual

Page 8: Remove terminal block cover

background image

8

2.

Screw in leveling legs

INSTALL LEVELING LEGS

To avoid damaging floor, use a large flat piece of cardboard

from dryer carton; place under entire back edge of dryer.

Firmly grasp dryer body (not console panel) and gently lay

dryer down on cardboard.

NOTE:

Residual water from factory testing may drain when

dryer is laying on its side.

1.

Prepare dryer for leveling legs

Using a wrench and tape measure, screw leveling legs into

leg holes until bottom of foot is approximately 1/2" (13 mm)

from bottom of dryer.

Now stand the dryer on its feet. Slide the dryer until it is

close to its final location.

ELECTRICAL INSTALLATION –

U.S.A. ONLY

Remove hold-down screw and terminal block cover.

1.

Choose electrical connection type

Power supply cord 4-wire receptacle

(NEMA Type 14-30R).

Go to “Power Supply Cord Connection.”

3-wire direct connection:

Go to “Direct Wire Connection.”

4-wire direct connection:

Go to “Direct Wire Connection.”

Power supply cord 3-wire receptacle

(NEMA Type 10-30R).

Go to “Power Supply Cord Connection.”

NOTE:

If local codes do not permit connection of a

cabinet-ground conductor to neutral wire, go to “Optional

External Ground for 3-Wire Connection.” This connection

may be used with either a power supply cord or a direct

wire connection.

2.

Remove terminal block cover

Before you start, disconnect power.