beautypg.com

Whirlpool 27 Inch Ventless Electric Dryer Installation Instructions User Manual

Page 12

background image

12

4-Wire Direct Wire Connection

IMPORTANT:

A 4-wire connection is required for mobile homes

and where local codes do not permit 3-wire connections.

1.

Prepare your 4-wire cable

for direct connection

1"

(25 mm)

3

1

2

"

(89 mm)

5"

(127 mm

)

2.

Attach direct wire cable to strain relief

Put direct wire cable through the strain relief. The strain

relief should have a tight fit with the dryer cabinet and be in

a horizontal position. Tighten strain relief screw against the

direct wire cable.

Direct wire cable must have 5 ft. (1.52 m) of extra length so

dryer may be moved if needed.

Strip 5" (127 mm) of outer covering from end of cable,

leaving bare ground wire at 5" (127 mm). Cut 1

1

/

2

" (38 mm)

from remaining 3 wires. Strip insulation back 1" (25 mm).

Shape ends of wires into hooks.

3-wire direct connection:

Go to “3-Wire Direct Wire Connection.”

4-wire direct connection:

Go to “4-Wire Direct Wire Connection.”

If your wiring looks like this:

4.

Connect ground wire

F

A

Connect ground wire (green or bare) (F) of direct wire cable

under green external ground conductor screw (A). Tighten

screw.

2.

Prepare to connect neutral ground

wire and neutral wire

E

B

A

Remove center terminal block screw (B). Remove neutral

ground wire (E) from green external ground conductor screw (A).

3.

Connect neutral ground wire and

neutral wire

C

E

B

Connect neutral ground wire (E) and place

hooked end (hook facing right) of neutral wire

(white or center wire) (C) of direct wire cable

under center screw of terminal block (B).

Squeeze hooked ends together and tighten screw.