beautypg.com

Connect outlet hose – Whirlpool 27 Inch Ventless Electric Dryer Installation Instructions User Manual

Page 14

background image

14

Connect neutral ground wire (E) and neutral wire (white or

center wire) (C) of power supply cord or cable under center,

terminal block screw (B). Tighten screw.

Place ends of remaining wires under outer terminal block

screws. Tighten screws.

2.

Connect neutral ground wire and

neutral wire

C

E

B

3.

Connect remaining wires

Connect a separate copper ground wire (G) under the green

external ground conductor screw (A) to an adequate ground.

Finally, reinsert tab of terminal block cover into slot of dryer

rear panel. Secure cover with hold-down screw. Now, go to

“Connect Outlet Hose.”

4.

Connect external ground wire

G

A

CONNECT OUTLET HOSE

1.

Attach hose

Attach the goose-neck fitting of the provided 6 ft. (1.82 m)

drain hose to the drain valve at the bottom of dryer back

panel. Screw on coupling by hand until it is seated on valve

connector.

2.

Tighten coupling

Using channel locks, tighten the coupling an additional

two-thirds turn.

NOTE:

Do not over-tighten. Damage to the coupling can

result.

4.5"

(114 mm)

4.5"

(114 mm)

4.5"

(114 mm)

4.5"

(114 mm)

4.5"

(114 mm)

4.5"

(114 mm)

3.

Secure drain hose system

Secure drain hose to laundry tub leg, drain standpipe, or inlet

hoses for wall standpipe with cable tie.

Laundry Tub

Standpipe

Wall