Using LANVIEW
Troubleshooting
4-3
describes the LED indications and provides recommended actions as appropriate.
Refer to the HSIM or VHSIM user’s guide for a description of the HSIM or VHSIM LED
indications.
NOTE: The terms flashing, blinking, and solid used in
indicate the
following:
Flashing indicates an LED is flashing randomly.
Blinking indicates an LED is flashing at a steady rate (approximately 50% on, 50% off).
Solid indicates a steady LED light. No pulsing.
Table 4-1
LANVIEW LEDs
LED
Color
State
Recommended Action
PWR
Off
Device electronics not
receiving power from power
supply(ies).
1. Ensure that the power cords are
plugged in correctly and that
there is power at the power
source.
2. Contact Enterasys Networks for
assistance.
Green
Functional. Power
supply(ies) operating
normally.
None.
Amber
Indicates loss of power
supply redundancy.
1. Ensure that the power cords are
plugged in correctly and that
there is power at the power
source.
2. Contact Enterasys Networks for
assistance.