Using LANVIEW
Enterasys SecureStack B2 Installation Guide 4-5
UP
Off
No valid connection to switch stackdown
connector.
1. Make sure the switch connected to the
stackdown connector is powered on.
2. Replace cable with a known good one.
3. If the problem still exists, contact
Enterasys Networks for technical
support.
Green
Solid. Valid connection to switch stackdown
connector.
Blinking. Information is being transferred via the
high-speed stacking cable.
None.
Manager
Off
Switch is operating as a Member in the stack.
None.
Green
Solid. Switch is operating as the Manager of the
stack.
None.
RPS
Off
RPS not in use.
Internal power supply failure.
None.
If an RPS is connected to the switch, it
should be providing power, perform the
following:
1. Ensure the RPS is powered on.
2. Ensure that the AC power cord to the
RPS is plugged in correctly and that
there is power at the AC power source.
3. Replace the power cord with a known
good one.
4. Ensure the DC power cord from the
RPS to the switch is plugged in
correctly.
5. If the problem persists, contact
Enterasys Networks for technical
support.
Amber
Solid. The switch internal power supply failed,
and the RPS is providing the proper power to the
switch.
None.