Using LANVIEW
4-4 Troubleshooting
Table 4-1 LANVIEW LEDs
LED
Color
State
Recommended Action
CPU
Off
Power disconnected.
If the LED remains off after connecting AC
power or DC power from an RPS, check
the following:
1. Make sure there is power at the power
source (AC source and RPS if
applicable).
2. Replace the power cord with a known
good one or check the continuity of the
power cord.
3. If the switch still does not power up, the
system may have a fatal error. Contact
Enterasys Networks for technical
support.
Red
Solid. Boot-up failed.
If the LED remains red for several
minutes, the system may have a fatal
error. Contact Enterasys Networks for
technical support.
Amber
Solid. Diagnostics are running.
If the LED remains amber for more than
several minutes, contact
Enterasys Networks for technical support.
Blinking. Code image is being downloaded.
None.
Green
Solid. System is fully functional.
None.
Blinking. Boot-up in process.
None.
DOWN
Off
No valid connection to switch stackup connector.
1. Make sure the switch connected to the
stackup connector is powered on.
2. Replace cable with a known good one.
3. If the problem still exists, contact
Enterasys Networks for technical
support.
Green
Solid. Valid connection to switch stackup
connector.
Blinking. Information is being transferred
through the high-speed stacking cable.
None.