Using LANVIEW

4-4 Troubleshooting

Table 4-1 LANVIEW LEDs

LED

Color

State

Recommended Action

CPU

Off

Power disconnected.

If the LED remains off after connecting AC
power or DC power from an RPS, check
the following:

1. Make sure there is power at the power

source (AC source and RPS if
applicable).

2. Replace the power cord with a known

good one or check the continuity of the
power cord.

3. If the switch still does not power up, the

system may have a fatal error. Contact
Enterasys Networks for technical
support.

Red

Solid. Boot-up failed.

If the LED remains red for several
minutes, the system may have a fatal
error. Contact Enterasys Networks for
technical support.

Amber

Solid. Diagnostics are running.

If the LED remains amber for more than
several minutes, contact
Enterasys Networks for technical support.

Blinking. Code image is being downloaded.

None.

Green

Solid. System is fully functional.

None.

Blinking. Boot-up in process.

None.

DOWN

Off

No valid connection to switch stackup connector.

1. Make sure the switch connected to the

stackup connector is powered on.

2. Replace cable with a known good one.

3. If the problem still exists, contact

Enterasys Networks for technical
support.

Green

Solid. Valid connection to switch stackup
connector.
Blinking. Information is being transferred
through the high-speed stacking cable.

None.