Rack Mounting the Switch

SecureStack B2 Installation Guide 3-9

Rack Mounting the Switch

To install the switch in a 19‐inch rack, you need: 

Two rackmount brackets and mounting screws (rackmount kit) shipped with the 
switch.

Four user‐supplied screws to attach the switch to a standard 19‐inch rack.

Guidelines for Rackmount Installation

The installation site must be within reach of the network cabling and meet the 
requirements listed below:

Appropriate grounded power receptacles must be located within 152 cm (5 ft) of the 
location.

A temperature of between 5°C (41°F) and 40°C (104°F) must be maintained at the 
installation site with fluctuations of less than 10°C (18°F) per hour.

Attaching Brackets and Installing in Rack

Proceed as follows to install the switch into a 19‐inch rack:

1.

Attach the rackmount brackets to the switch, as shown in 

Figure 3‐5

, using the eight 

M3x6 mm flathead screws shipped with the switch. 

Note: To ensure proper ventilation and prevent overheating, leave a minimum clearance
space of 5.1 cm (2.0 in.) at the left, right, and rear of the switch.

Warning: Before rack-mounting the switch, ensure that the rack can support it without
compromising stability. Otherwise, personal injury and/or equipment damage may result.

Advertencia: Antes de montar el equipo en el rack, asegurarse que el rack puede
soportar su peso sin comprometer su propia estabilidad, de otra forma, daño personal o
del equipo puede ocurrir.

Warnhinweis: Überzeugen Sie sich vor dem Einbau des Gerätes in das Rack von dessen
Stabilität, ansonsten könnten Personenschäden oder Schäden am Gerät die Folge sein.