Make Electrical Connections

Complete Installation

Determine and make all necessary cuts in the

wall or roof for the vent system. Install the vent

system before installing the cabinet hood insert.

See the “Venting Requirements” section.
Determine the location where the power supply

cable will be run through the wall.
Drill a 1¹⁄

4

” (3.2 cm) hole at this location.

Pull enough power supply cable through the wall

to allow for easy connection to the terminal box.
Remove terminal box cover and set aside.
Remove knockout from the top of the vent hood

and install a UL listed or CSA approved ½”

(1.3 cm) strain relief.
Place the hood insert near its mounting position

and run the power supply cable through the strain

relief into terminal box (enough to make connection).
Tighten the strain relief screws.
Using 2 or more people, lift the hood insert into

hood cabinet.
Fasten the hood insert using four 5 x 45 mm

screws to the hood cabinet and tighten securely.

EXCESSIVE WEIGHT HAZARD
USE TWO OR MORE PEOPLE TO MOVE AND
INSTALL HOOD INSERT.
FAILURE TO DO SO CAN RESULT IN BACK OR
OTHER INJURY.



1.

2.

3.
4.

5.
6.

7.

8.
9.

10.

Check that all installation parts have been

removed from the shipping carton.
Using 2 or more people, lift hood insert onto

covered surface.
Remove the filters. See the “Cleaning”

section on page 15.

Install Hood insert into

Hood Cabinet


The hood insert attaches to the hood cabinet using
four mounting screws and washers.
NOTE: Hood cabinet must be capable of supporting
75 lb (34 kg).
Prepare Hood Insert for mounting into cabinet

Mark the locations for the four mounting screws

on the hood cabinet as shown below.
Using a ¹⁄

8

” (3 mm) drill bit, drill the 4 holes.









A

B

C

D

E

F





Mark the cutout for the rectangular clearance hole

for the upper hood insert motor housing as shown.
Using a jigsaw or keyhole saw, cut out the rectan-

gular clearance hole for the upper hood insert housing.












4.

5.

1.

2.

3.

4.

MOUNTING HOLE DIMENSIONS

Hood

Insert

DIM B

DIM C

DIM D

DIM E

DIM F

EI30HI55KS

5

1

2

” (13.9 cm)

11” (28 cm)

12

5

32

” (30.9 cm)

24

5

16

” (61.8 cm)

1/8” (3mm)

EI36HI55KS

6” (15.1 cm)

10

1

8

” (25.7 cm)

14

15

16

” (38 cm)

29

13

16

” (75.8 cm)

1/8” (3mm)

EI48HI55KS

6” (15.1 cm)

10

1

8

” (25.7 cm)

14

15

16

” (38 cm)

29

13

16

” (75.8 cm)

1/8” (3mm)

A. Centerline

Mounting

holes

Upper Hood

Insert Motor Housings

4 mounting
screws

UPPERHOOD MOTOR HOUSINgS DIMENSIONS

Hood

Insert

DIM B

DIM C

DIM D

DIM E

EI30HI55KS

4

13

32

” (11.2 cm)

13

3

16

” (33.5 cm)

11

13

32

” (29 cm)

22

13

16

” (58 cm)

EI36HI55KS

4

13

32

” (11.2 cm)

13

3

16

” (33.5 cm)

14

3

16

” (36 cm)

28

3

8

” (72 cm)

EI48HI55KS

4

13

32

” (11.2 cm)

13

3

16

” (33.5 cm)

14

3

16

” (36 cm)

28

3

8

” (72 cm)

A. Centerline

This manual is related to the following products: