Control command table, Power control/input mode selection, Picture menu – Sharp PN-H801 User Manual
Page 33: Controlling the monitor with a pc (rs-232c)
33
E
Control command table
How to read the command table
Command:
Command field (See page 31.)
Direction:
W When the “Parameter” is set in the parameter field (see page 31), the command functions as described
under “Control/Response Contents”.
R The returned value indicated under “Reply” can be obtained by setting “????” or “?
” in the
parameter field (see page 31).
Parameter:
Parameter field (See page 31.)
Reply:
Response (Returned value)
TIPS
• In standby mode, the only command that is used is POWER CONTROL.
• When POWER SAVE MODE is ON, control via LAN is not possible in standby mode.
When POWER SAVE MODE is OFF, control is not possible in standby mode.
Power control/Input mode selection
Function
Command Direction
Parameter
Reply
Control/Response contents
POWER CONTROL
POWR
W
0
Switches to standby mode.
1
Returns from standby mode.
R
0 Standby mode
1 Normal mode
INPUT MODE SELECTION
ITGD
W
0
Toggle change for input mode.
IAVD
WR
1
1 HDMI1
2
2 HDMI2
3
3 HDMI3
4
4 HDMI4
5
5 D-SUB
6
6 MULTIMEDIA (USB port/Internal memory)
PICTURE menu
Function
Command Direction
Parameter
Reply
Control/Response contents
PICTURE MODE
AVMD
W
0
Toggle change for input mode.
1
AV
2
MOVIE
3
GAME
6
VIVID
7
PC
9
sRGB
11
PHOTO
20
Adobe RGB SIM.
R
1 AV
2 MOVIE
3 GAME
6 VIVID
7 PC
9 sRGB
11 PHOTO
20 Adobe RGB SIM.
BRIGHT
VLMP
WR
-16-16
-16-16
CONTRAST
CONT
WR
0-40
0-40
BLACK LEVEL
BLVL
WR
-30-30
-30-30
TINT
TINT
WR
-30-30
-30-30
COLORS
COLR
WR
-30-30
-30-30
SHARPNESS
SHRP
WR
0-20
0-20
Controlling the Monitor with a PC (RS-232C)