Technical Specification
B.5.3.2
High Speed Data over Ethernet
This connector is located at the back of the unit using the RJ-45 Ethernet port and is
enabled through the license key (RX1290/SWO/HSETHER).
Table B.26 High Speed Data Over Ethernet Connector
Item Specification
Safety status
SELV
Connector Type
RJ-45 (100BaseT)
Connector designation
10/100BaseT
Data rates (bit/s)
5 Mbps
Standards
ETSI EN 301 192 v.1.2.1 (1999-06), Section 4
De-encapsulation type
Data-Piping (Proprietary)
B.5.4
SNMP Remote Control Connector
Table B.27 SNMP Control Connector
Item Specification
Safety status
SELV
Connector type
RJ-45 (100BaseT)
Connector designation
10/100BaseT
Standard
Ericsson SNMP Control MIB
B.5.5
Alarm Connector
Table B.28 Relay Alarm Output Specification
Item
Specification
Safety status
SELV
Connector type
9-way D-type female
Connector designation:
ALARM
Contact Configuration
SPDT (Change-over)
All volt-free contacts, fully isolated.
Contact Rating
1 A at 24 V DC
1 A at 50 V AC
Maximum Switching Current
1 A
Maximum Switching Voltage
50 Vdc / 30 V AC
EN/LZT 790 0003/2 R1A